Zipper closure
1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying
fabric for superior performance.
REGULAR FIT - US standard sizes. An athletic fit that sits close to the
body
for a wide range of motion, designed for optimal performance and all day
comfort.
FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them
in
place during workout
1、Safe and Reliable
●CATL battery cell
●High IP protection rating
●Pack level short-circuit protection
●Innovative air duct design
●4 level of safety protection
2、Intelligent Control●Optimized operation strategy by EMS●OTA maintenance and monitoring●Unmanned operation
3、Flexible Configuration
●Standardized interface for flexible access
●Plug and play modular design
●Expandable to MWh
●Integrated transportation
4、Economical and Efficient
●Efficient thermal management design
●Replaceable pack for easy O&M
●Longer battery life cycle
4 Level of Safety Protection
-
Cell safety
●CATL LFP cell
●Strict incoming inspection
●Thermal insulation pad between each cell (aerogel)CATL LFP cell
-
Pack safety
●IP67 protection rating
●Pack-level short circuit protection (fuse)
●Pack-level fire suppression module
-
Pack safety
●IP54 protection rating
●Explosion-proof fans for the entire cabinet
●System-level fire suppression module
-
Cloud monitoring
●Real-time data for each cell
●Remote monitoring and predictive diagnosis of SOH
-
Off Grid Island
-
Commercial Buildings
-
Industrial Parks
-
Solar Storage ChargingIntegration System
-
Distribution Grid Expansion
Product Type
|
ANPLHULK100200
|
DC Parameters
|
Battery Type Battery Rated Capacity Battery System Configuration Battery Rated Capacity [kWh] Rated Voltage [V] Voltage Range [V] Depth Of Discharge Life Cycle
|
Lithium-ion battery (CATL) 3.2V / 280Ah 1P224S 200 716.8 627.2 ~ 806.4 90% ≥8000 (EOL>60%, 25℃)
|
AC Parameters
|
Grid Voltage Range [V] Grid Frequency Range [Hz] AC Mode Isolation Mode Rated Charge / Discharge Power Operating Mode
|
AC400 (-15%~+10%) 50 / 60 (±2.5) 3-Phase 3-Wire (3P3W) No isolation connected to the grid 100kW / AC On-grid / off-grid (optional isolation transformer)
|
System Parameter
|
Rated Charging and Discharging Rate System Efficiency Wiring Method Anti-Corrosion Grade Operating Temperature Range [℃] Relative Humidity Range Cooling Method Protection Rating Noise [dB] Operating Altitude [m] Weight [kg] Dimension [W*D*H] [mm] Communication Protocols
|
0.5P ≥88% Bottom in and bottom out C4-H -20 ~ +55 0 ~ 95% RH, no condensation Air-Liquid Intelligent Cooling IP54 ≤70 (1m) 2000 (>2000 derating) ≤3000±100 (1546±5) × (1593±10) × (2260±5) ModBus-TCP / RS485 / CAN
|
Standard
|
IEC62619 / IEC63056 / IEC61000 / IEC62477 / UN38.3 / EN50549 / VDE4105
|